Mesaj gönder
MOORE AUTOMATION LIMITED
E-posta miya@mvme.cn Tel: 86-180-20776792
Evde > Ürünler > GE Kontrol Cihazı >
531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'tr', function () {});}
  • 531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'tr', function () {});}

531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'tr', function () {});}

Menşe yeri ABD
Marka adı GE
Sertifika CO.CQ
Model numarası 531X152IOCAKG1
Ürün Detayları
Manufacture Year:
2020
P / N:
531X152IOCAKG1
Uygulama:
Nuclear Power Plant
Sağlama süresi:
Stock
Açıklama:
GE
Adı:
531X152IOCAKG1 GE Controller Process Interface Board
Vurgulamak: 

general electric board

,

ge multilin relaysfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en'

Ödeme ve Gönderim Koşulları
Min sipariş miktarı
1
Fiyat
inquiry
Ambalaj bilgileri
fabrika mühürlü ile yeni ve orijinal
Teslim süresi
bugün
Ödeme koşulları
T/T
Yetenek temini
Günde 10 parça
Ürün Açıklaması

 

Product Specification

Brand/Manufacturer GE/USA
Part Number

531X152IOCAKG1

Alternate Part Number  531X152IOCAKG1
Description

Process Interface Board

Dimennsions 3*13*10cm
Weight 0.24kg

 

Product Details
The timer shown in Figure 4.7 is reset on the first scan. On the second scan, it

starts timing. After 5seconds, it energizes a bit called“COMINIT”, which is used

to trigger the COM_REQ. It also energizes a bit called“RTMINIT”. On the next scan,

“COMINIT”is turned off, and the RTMINIT bit causes the timer to be disabled indefinitely.

Temporary (%T) data types are used for these two bits, so that their state is not

retained through a reset.After the COM_REQ has been executed, it writes status

data to the status register specified in theCOM_REQ data block. This register is

monitored by the ladder logic to determine the successful (or unsuccesful) result

of the COM_REQ. It is good practice to clear the status register just prior to execution
of the COM_REQ, ensuring the validity of future data.

 

531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'tr', function () {});} 0            531X152IOCAKG1 GE Controller Process Interface Boardfunction gtElInit() {var lib = new google.translate.TranslateService();lib.translatePage('en', 'tr', function () {});} 0            

 

More Products

GE DS200LDCCH1A GE 531X133PRUAMG1
GE DS200TBQBG1ACB GE 531X139APMASM7
GE IS2020ISUCG3A GE 531X124MSDAJG2
GE DS200TCDAH1BHE GE 531X300CCHAGM5
GE DS200TCDAH1BHD GE DS200LPPAG1A
GE 531X121PCRALG1 GE IC660CBB902K
GE DS200LPPAG1A GE IC600BF929K
GE IC600FP832K GE IC660FP8900K

 

Contact Us

miya@mvme.cn(Click)

 

Email: miya@mvme.cn                   QQ: 2851195450

Tel: 86-18020776792                     Skype: miyazheng52

İstediğiniz Zaman Bize Ulaşın

86-180-20776792
32D kat, GuoMao binası, Hubin Güney Yolu, Siming Bölgesi, Xiamen Şehri , Fujian Eyaleti , Çin.
Sorgunuzu doğrudan bize gönderin